From: Jon Maloy <jon.ma...@ericsson.com>
Date: Fri, 25 Nov 2016 10:35:02 -0500

> In commit e4bf4f76962b ("tipc: simplify packet sequence number
> handling") we changed the internal representation of the packet
> sequence number counters from u32 to u16, reflecting what is really
> sent over the wire.
> 
> Since then some link statistics counters have been displaying incorrect
> values, partially because the counters meant to be used as sequence
> number snapshots are now used as direct counters, stored as u32, and
> partially because some counter updates are just missing in the code.
> 
> In this commit we correct this in two ways. First, we base the
> displayed packet sent/received values on direct counters instead
> of as previously a calculated difference between current sequence
> number and a snapshot. Second, we add the missing updates of the
> counters.
> 
> This change is compatible with the current netlink API, and requires
> no changes to the user space tools.
> 
> Signed-off-by: Jon Maloy <jon.ma...@ericsson.com>

Applied.