From: Sven Eckelmann <s...@narfation.org>

The shutdown of an batman-adv interface can happen with one of its slave
interfaces still being in the BATADV_IF_TO_BE_ACTIVATED state. A possible
reason for it is that the routing algorithm BATMAN_V was selected and
batadv_schedule_bat_ogm was not yet called for this interface. This slave
interface still has to be set to BATADV_IF_INACTIVE or the batman-adv
interface will never reduce its usage counter and thus never gets shutdown.

This problem can be simulated via:

    $ modprobe dummy
    $ modprobe batman-adv routing_algo=BATMAN_V
    $ ip link add bat0 type batadv
    $ ip link set dummy0 master bat0
    $ ip link set dummy0 up
    $ ip link del bat0
    unregister_netdevice: waiting for bat0 to become free. Usage count = 3

Reported-by: Matthias Schiffer <mschif...@universe-factory.net>
Signed-off-by: Sven Eckelmann <s...@narfation.org>
Signed-off-by: Marek Lindner <mareklind...@neomailbox.ch>
Signed-off-by: Antonio Quartulli <a...@unstable.cc>
---
 net/batman-adv/hard-interface.c | 3 +--
 1 file changed, 1 insertion(+), 2 deletions(-)

diff --git a/net/batman-adv/hard-interface.c b/net/batman-adv/hard-interface.c
index b22b2775a0a5..c61d5b0b24d2 100644
--- a/net/batman-adv/hard-interface.c
+++ b/net/batman-adv/hard-interface.c
@@ -572,8 +572,7 @@ void batadv_hardif_disable_interface(struct 
batadv_hard_iface *hard_iface,
        struct batadv_priv *bat_priv = netdev_priv(hard_iface->soft_iface);
        struct batadv_hard_iface *primary_if = NULL;
 
-       if (hard_iface->if_status == BATADV_IF_ACTIVE)
-               batadv_hardif_deactivate_interface(hard_iface);
+       batadv_hardif_deactivate_interface(hard_iface);
 
        if (hard_iface->if_status != BATADV_IF_INACTIVE)
                goto out;
-- 
2.8.1