Nick Shank <[EMAIL PROTECTED]> writes:
> I happened to read this as I was on my way out of the office for the
> week (yay for vacation, and a paid one at that) I don't recall the
> exact error, but on 3 different SMP slot 1 machines, bsd.mp under 3.9
> complains about apic, and dies. PS shows swapper as the only thing
> active. Will look more into it on Friday when I get back, and post
> what I find. Although, the thought of going back a version or two
> seems like it might work, as I know I've had 3.7 or 3.8 working on at
> least one of my dual slot 1 machines...
> Hope that helps at least a little bit,
> Nick
>
>
My Compaq ProLiant 2500 server has two Pentium Pro on socket 8, not on
slot 1.
$ dmesg | egrep "GENERIC|cpu"
OpenBSD 3.9 (GENERIC) #617: Thu Mar 2 02:26:48 MST 2006
[EMAIL PROTECTED]:/usr/src/sys/arch/i386/compile/GENERIC
cpu0: Intel Pentium Pro ("GenuineIntel" 686-class, 256KB L2 cache) 199 MHz
cpu0: FPU,V86,DE,PSE,TSC,MSR,PAE,MCE,CX8,APIC,SEP,MTRR,PGE,MCA,CMOV
cpu0 at mainbus0
I don't know if it makes a difference for this kernel panic:
[...]
ioapic0 at mainbus0: apid 2 pa 0xfec00000, version 11, 28 pins
ioapic0: misconfigured as apic 0, remapped to apic 2
panic: can't deal with not-all-lapics interrupt yet!
[...]
Unfortunately, this server is in production now and I can't go back in
3.7 or 3.8 to see if it works.
Thanks again Nick.
Francois
--
http://www.chambaud.org