On 26.7.2012. 18:31, Patrick Lamaiziere wrote:
> Hello,
> 
> We have just noticed that pflow (v5) sometime (but often) uses a
> StartTime value which is later than the EndTime.
> So the duration is interpreted 4294966.296000000 secondes.
> This confuses our collector (nfsen).
> 
> (wireshark)
>    pdu 19/30
>         SrcAddr: 194.57.169.116 (194.57.169.116)
>         DstAddr: 129.20.254.1 (129.20.254.1)
>         NextHop: 0.0.0.0 (0.0.0.0)
>         InputInt: 0
>         OutputInt: 0
>         Packets: 3
>         Octets: 164
>         [Duration: 4294966.296000000 seconds]
>             StartTime: 251367.000000000 seconds
>             EndTime: 251366.000000000 seconds
>         SrcPort: 55680
>         DstPort: 53
>         padding
>         TCP Flags: 0x00
>         Protocol: 6
>         IP ToS: 0x00
>         SrcAS: 0
>         DstAS: 0
>         SrcMask: 0 (prefix: 194.57.169.116/32)
>         DstMask: 0 (prefix: 129.20.254.1/32)
>         padding
> 
> Any clue?
> Thanks, regards.
> 

i have same problem, 4294906.296 is the most common flow duration in
nfsen :)

Reply via email to