I don't know.  Altera has generally required talkback to be enabled
when using the free version of the tools and targeting any of the
"complex" FPGA families (SoC+FPGA or the parts with high-speed
transceivers) but they may have changed things with 17.1.

I suspect you'll still need to enable talkback, but it may require a
different method.  I haven't worked with 17.1 yet even on my main
Windows development system, much less in a Docker VM.

NOTE: IIRC, when I was trying to get 15.1 working as a Docker image,
the "official" way to enable talkback required running a GUI and
clicking some buttons which was pretty hard to do from within the
Docker build.  I tracked down what was happening behind the scenes,
and managed to get the tb2_install program to do what I needed without
requiring user input.  You will likely have to figure this out
yourself if you're wanting to make a Docker image, or just run the
Quartus GUI and enable talkback if you're working with a "regular" system.

On 4/30/2018 10:16 AM, mugginsac wrote:
> I discovered that tb2_install is included in Quartus 15.1 but not in 17.1. 
> Does that mean that tb2_install is no longer required with the new version 
> of Quartus?
> 
> Thanks,
> Alan
> 
> On Saturday, May 28, 2016 at 10:59:07 AM UTC-7, DeWayne Young wrote:
>>
>> Starting the Quartus shell is the first problem from the GitHub readme file
>> altera/15.1/embedded/embedded_command_shell.sh  
>> this does not exist
>>
>> I installed the Quartus Lite version which installs into alter_lite and 
>> not altera
>> There are no embedded directories at all
>>
>> attached it the make all output results.
>>
>> I have a feeling that perhaps something is missing from the Quartus 
>> Install of 15.1 and the updates upgrade.
>>
>> But OMG this is allot of FUN
>>
>>
> 


-- 
Charles Steinkuehler
[email protected]

-- 
website: http://www.machinekit.io blog: http://blog.machinekit.io github: 
https://github.com/machinekit
--- 
You received this message because you are subscribed to the Google Groups 
"Machinekit" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
Visit this group at https://groups.google.com/group/machinekit.
For more options, visit https://groups.google.com/d/optout.