On Tue Mar 3 10:42:35 2026 +0200, Svyatoslav Ryhel wrote:
> Increase maximum VI clock frequency to 450MHz to allow correct work with
> high resolution camera sensors.
>
> Tested-by: Luca Ceresoli <[email protected]> # tegra20, parallel
> camera
> Signed-off-by: Svyatoslav Ryhel <[email protected]>
> Reviewed-by: Mikko Perttunen <[email protected]>
> Signed-off-by: Hans Verkuil <[email protected]>
Patch committed.
Thanks,
Hans Verkuil
drivers/staging/media/tegra-video/tegra20.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
---
diff --git a/drivers/staging/media/tegra-video/tegra20.c
b/drivers/staging/media/tegra-video/tegra20.c
index 7ceefd920cd6..bf8755698610 100644
--- a/drivers/staging/media/tegra-video/tegra20.c
+++ b/drivers/staging/media/tegra-video/tegra20.c
@@ -598,7 +598,7 @@ const struct tegra_vi_soc tegra20_vi_soc = {
.ops = &tegra20_vi_ops,
.hw_revision = 1,
.vi_max_channels = 2, /* TEGRA_VI_OUT_1 and TEGRA_VI_OUT_2 */
- .vi_max_clk_hz = 150000000,
+ .vi_max_clk_hz = 450000000,
.has_h_v_flip = true,
};
_______________________________________________
linuxtv-commits mailing list -- [email protected]
To unsubscribe send an email to [email protected]