Dear Michael, in message <E1836A7F3557D311A14000805F9F36FCD4E383 at usdfo011.usac.danfoss.net> you wrote: > > I have an Embedded Planet with a LITE_DW Motorola 823 PPC using a HIOX > interface board. I am trying to debug a program sending out data from > ttyS1 and reading it back in on ttyS2. The latest patch has been applied
I guess you are using the SMC ports for the ttyS* ? > I want to be able to send any char over the serial link, so I've resorted to > using "raw" mode. The problem is that if an overrun occurs on the receive > side, there is nothing I can sense to indicate this situation. Has anyone > run into this problem and/or is there a solution to my dilemma? In raw mode you're kind of lost - the SMC's don't have any handshake signals. You could switch to use SCC's instead. We have a modified driver that supports full HW handshake on all SCC's (and you can configure the number and size of I/O buffers to optimize for throughput). Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-4596-87 Fax: (+49)-8142-4596-88 Email: wd at denx.de A direct quote from the Boss: "We passed over a lot of good people to get the ones we hired." ** Sent via the linuxppc-embedded mail list. See http://lists.linuxppc.org/