On Tue, Sep 1, 2015 at 2:29 PM, Maxime Ripard <[email protected]> wrote: > On Sat, Aug 29, 2015 at 10:07:12AM +0800, Chen-Yu Tsai wrote: >> >> >> + >> >> >> +&axp221 { >> >> >> + compatible = "x-powers,axp221"; >> >> >> + interrupt-controller; >> >> >> + #interrupt-cells = <1>; >> >> >> + >> >> >> + regulators { >> >> >> + /* Default work frequency for buck regulators */ >> >> >> + x-powers,dcdc-freq = <3000>; >> >> >> + >> >> >> + /* supplies for dc1sw & dc5ldo are connected internally >> >> >> */ >> >> >> + dcdc1-supply = <®_dcdc1>; >> >> >> + dcdc5-supply = <®_dcdc5>; >> >> > >> >> > so the parent regulator of DCDC1 is DCDC1 ? >> >> >> >> These probably aren't the best names. These are the supplies for DC1SW and >> >> DC5LDO, respectively. They are connected internally, so there aren't named >> >> pins for them. The comment above explains it, though probably not clearly >> >> enough. Furthermore, the input pins for DCDC1/5 are VIN1/5. >> > >> > I'm not quite sure I understand. They're connected internally but they >> > have pins ? >> >> Internally, DCDC1's output feeds the input for DC1SW (which is just a switch >> BTW) and DCDC5's output feeds DC5LDO (which is an LDO). Both these extra >> regulators have separate controls. There are no external pins to name the >> supplies after, so I just named them after which regulator supplies them. > > Well, there is. dc5ldo and dc1sw. And it is also how you called these > regulators in your DT, so it would make much more sense to have it > listed as such.
I was under the impression that we name them after the input pins. The names are also documented in Documentation/devicetree/bindings/mfd/axp20x.txt Do you want to change them? Regards ChenYu -- You received this message because you are subscribed to the Google Groups "linux-sunxi" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.