On Sun, 28 Feb 2010 20:18:50 +0100
Antonio Ospite <osp...@studenti.unina.it> wrote:

> Maybe we could just use
>       V4L2_CID_POWER_LINE_FREQUENCY_DISABLED  = 0,
>       V4L2_CID_POWER_LINE_FREQUENCY_50HZ      = 1,
> 
> It looks like the code matches the DISABLED state (writing 0 to the
> register). Mosalam?

I don't know the ov772x sensor. I think it should look like the ov7670
where there are 3 registers to control the light frequency: one
register tells if light frequency filter must be used, and which
frequency 50Hz or 60Hz; the two other ones give the filter values for
each frequency.

-- 
Ken ar c'hentaƱ |             ** Breizh ha Linux atav! **
Jef             |               http://moinejf.free.fr/
--
To unsubscribe from this list: send the line "unsubscribe linux-media" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to