The Zotac RC2604323/01G and RC2604329/02BG remotes use the 32-bit
rc6 protocol and toggle bit 15 (0x8000) on repeated button presses,
like MCE remotes.

Add the customer code 0x80340000 to the 32-bit rc6 toggle
handling code to get proper scancodes and toggle reports.

Signed-off-by: Matthias Reichl <h...@horus.com>
---
LibreELEC bug report and more info are here:
https://forum.libreelec.tv/thread/14388-ir-remote-malfunction-after-upgrade-to-le-9-0/

diff --git a/drivers/media/rc/ir-rc6-decoder.c 
b/drivers/media/rc/ir-rc6-decoder.c
index d96aed1343e4..5cc302fa4daa 100644
--- a/drivers/media/rc/ir-rc6-decoder.c
+++ b/drivers/media/rc/ir-rc6-decoder.c
@@ -40,6 +40,7 @@
 #define RC6_6A_MCE_TOGGLE_MASK 0x8000  /* for the body bits */
 #define RC6_6A_LCC_MASK                0xffff0000 /* RC6-6A-32 long customer 
code mask */
 #define RC6_6A_MCE_CC          0x800f0000 /* MCE customer code */
+#define RC6_6A_ZOTAC_CC                0x80340000 /* Zotac customer code */
 #define RC6_6A_KATHREIN_CC     0x80460000 /* Kathrein RCU-676 customer code */
 #ifndef CHAR_BIT
 #define CHAR_BIT 8     /* Normally in <limits.h> */
@@ -246,6 +247,7 @@ static int ir_rc6_decode(struct rc_dev *dev, struct 
ir_raw_event ev)
                                switch (scancode & RC6_6A_LCC_MASK) {
                                case RC6_6A_MCE_CC:
                                case RC6_6A_KATHREIN_CC:
+                               case RC6_6A_ZOTAC_CC:
                                        protocol = RC_PROTO_RC6_MCE;
                                        toggle = !!(scancode & 
RC6_6A_MCE_TOGGLE_MASK);
                                        scancode &= ~RC6_6A_MCE_TOGGLE_MASK;
-- 
2.20.1