On Tue, May 20, 2014 at 12:12:16PM +0200, Alban Bedel wrote:
> When a regulator is defined using DT and it has a single voltage the
> regulator init always tries to apply this voltage. However it fails if
> the regulator isn't settable because it is using an internal low level
> function. To overcome this we now first query the regulator and only
> set it if needed.

Applied, thanks.