On 24/07/2026 at 14:35:39 -04, Frank Li <[email protected]> wrote:

> On Fri, Jul 17, 2026 at 05:59:21PM +0200, Miquel Raynal (Schneider Electric) 
> wrote:
>> There should be one single entry in the OF world, so that the way we
>> parse the DT is always the same. make sure this is the case by avoid
>> calling of_parse_phandle_with_args() from of_clk_get_parent_name(). This
>> is even more relevant as we currently fail to parse clock-ranges. As a
>> result, it seems to be safer to directly call of_parse_clkspec() there,
>> but doing so implies that we do not try the "clock-ranges" path if we
>> already found a "clocks" property..
>
> Sorry, I can't understand well what commit said.

I tried to reorder the commit sentences, hopefully it will make the text
easier to read.

Thanks,
Miquèl