Hi,

On Thu, Mar 11, 2021 at 07:57:35PM +0800, Xiaofeng Cao wrote:
> Change  'stanalone'      to  'standalone'
> Change  'mesaurement'    to  'measurement'
> Change  'nonvilatile'    to  'nonvolatile'
> Change  'unical'         to  'unique'
> Change  'unaccesable'    to  'unaccessible'
> Change  'correcpondent'  to  'correspond'
> 
> Signed-off-by: Xiaofeng Cao <[email protected]>
> ---

Thanks, queued. Please improve your patch subjects in the
future and use PATCHv2 instead of PATCH when sending a new
version.

-- Sebastian

>  drivers/power/supply/max1721x_battery.c | 14 +++++++-------
>  1 file changed, 7 insertions(+), 7 deletions(-)
> 
> diff --git a/drivers/power/supply/max1721x_battery.c 
> b/drivers/power/supply/max1721x_battery.c
> index 1b1a36f8e929..473e53cd2801 100644
> --- a/drivers/power/supply/max1721x_battery.c
> +++ b/drivers/power/supply/max1721x_battery.c
> @@ -1,6 +1,6 @@
>  /*
>   * 1-Wire implementation for Maxim Semiconductor
> - * MAX7211/MAX17215 stanalone fuel gauge chip
> + * MAX7211/MAX17215 standalone fuel gauge chip
>   *
>   * Copyright (C) 2017 Radioavionica Corporation
>   * Author: Alex A. Mihaylov <[email protected]>
> @@ -28,7 +28,7 @@
>  /* Number of valid register addresses in W1 mode */
>  #define MAX1721X_MAX_REG_NR  0x1EF
>  
> -/* Factory settings (nonvilatile registers) (W1 specific) */
> +/* Factory settings (nonvolatile registers) (W1 specific) */
>  #define MAX1721X_REG_NRSENSE 0x1CF   /* RSense in 10^-5 Ohm */
>  /* Strings */
>  #define MAX1721X_REG_MFG_STR 0x1CC
> @@ -105,7 +105,7 @@ static inline int max172xx_temperature_to_ps(unsigned int 
> reg)
>  /*
>   * Calculating current registers resolution:
>   *
> - * RSense stored in 10^-5 Ohm, so mesaurment voltage must be
> + * RSense stored in 10^-5 Ohm, so measurement voltage must be
>   * in 10^-11 Volts for get current in uA.
>   * 16 bit current reg fullscale +/-51.2mV is 102400 uV.
>   * So: 102400 / 65535 * 10^5 = 156252
> @@ -137,7 +137,7 @@ static int max1721x_battery_get_property(struct 
> power_supply *psy,
>               /*
>                * POWER_SUPPLY_PROP_PRESENT will always readable via
>                * sysfs interface. Value return 0 if battery not
> -              * present or unaccesable via W1.
> +              * present or unaccessible via W1.
>                */
>               val->intval =
>                       regmap_read(info->regmap, MAX172XX_REG_STATUS,
> @@ -334,9 +334,9 @@ static int devm_w1_max1721x_add_device(struct w1_slave 
> *sl)
>  
>       /*
>        * power_supply class battery name translated from W1 slave device
> -      * unical ID (look like 26-0123456789AB) to "max1721x-0123456789AB\0"
> -      * so, 26 (device family) correcpondent to max1721x devices.
> -      * Device name still unical for any numbers connected devices.
> +      * unique ID (look like 26-0123456789AB) to "max1721x-0123456789AB\0"
> +      * so, 26 (device family) correspond to max1721x devices.
> +      * Device name still unique for any number of connected devices.
>        */
>       snprintf(info->name, sizeof(info->name),
>               "max1721x-%012X", (unsigned int)sl->reg_num.id);
> -- 
> 2.25.1
> 