The SoC temperature can be retrieved from ADC channel 8 on all 32-bit
SoCs (Meson6, Meson8, Meson8b and Meson8m2). Add a "generic-adc-thermal"
instance to meson.dtsi so the thermal sensor is available for all SoCs.
If the temperature sensor calibration data is missing for a board then
the "generic-adc-thermal" will not probe and not register a thermal
sensor.

Signed-off-by: Martin Blumenstingl <[email protected]>
---
 arch/arm/boot/dts/meson.dtsi | 7 +++++++
 1 file changed, 7 insertions(+)

diff --git a/arch/arm/boot/dts/meson.dtsi b/arch/arm/boot/dts/meson.dtsi
index 5f074f7aa1a2..e0ca5f08d07d 100644
--- a/arch/arm/boot/dts/meson.dtsi
+++ b/arch/arm/boot/dts/meson.dtsi
@@ -298,6 +298,13 @@ efuse: nvmem@0 {
                };
        };
 
+       thermal_sensor: thermal-sensor {
+               compatible = "generic-adc-thermal";
+               #thermal-sensor-cells = <0>;
+               io-channels = <&saradc 8>;
+               io-channel-names = "sensor-channel";
+       };
+
        xtal: xtal-clk {
                compatible = "fixed-clock";
                clock-frequency = <24000000>;
-- 
2.29.2

Reply via email to