Hi Matthias,

On 20-07-29 09:14, Matthias Schiffer wrote:
> On Wed, 2020-07-29 at 09:11 +0200, Matthias Schiffer wrote:
> > In preparation for an update of the TQ-Systems TQMa7x/MBa7x DTS, add
> > the
> > QSPI controller to imx7s.dtsi.
> > 
> > Based-on-patch-by: Han Xu <[email protected]>
> > Signed-off-by: Matthias Schiffer <[email protected]>
> > ---
> > 
> > v2:
> > - renamed node and label
> > - reordered properties
> > (as suggested by Marco Felsch)
> 
> Ugh, I neglected to check for compile warnings after adjusting the node
> name. This now gives the following warning:
> 
> arch/arm/boot/dts/imx7s.dtsi:1165.24-1176.6: Warning (spi_bus_bridge): 
> /soc/bus@30800000/qspi@30bb0000: node name for SPI buses should be
> 'spi'
> 
> So I guess this should be called spi@ after all?

Unfortunately yes, this would cause a longer discussion but it still
seems wrong to me.

Regards,
  Marco

> > 
> > 
> >  arch/arm/boot/dts/imx7s.dtsi | 13 +++++++++++++
> >  1 file changed, 13 insertions(+)
> > 
> > diff --git a/arch/arm/boot/dts/imx7s.dtsi
> > b/arch/arm/boot/dts/imx7s.dtsi
> > index 1cfaf410aa43..22e4c38223bd 100644
> > --- a/arch/arm/boot/dts/imx7s.dtsi
> > +++ b/arch/arm/boot/dts/imx7s.dtsi
> > @@ -1162,6 +1162,19 @@
> >                             status = "disabled";
> >                     };
> >  
> > +                   qspi: qspi@30bb0000 {
> > +                           compatible = "fsl,imx7d-qspi";
> > +                           reg = <0x30bb0000 0x10000>, <0x60000000
> > 0x10000000>;
> > +                           reg-names = "QuadSPI", "QuadSPI-
> > memory";
> > +                           #address-cells = <1>;
> > +                           #size-cells = <0>;
> > +                           interrupts = <GIC_SPI 107
> > IRQ_TYPE_LEVEL_HIGH>;
> > +                           clocks = <&clks IMX7D_QSPI_ROOT_CLK>,
> > +                                   <&clks IMX7D_QSPI_ROOT_CLK>;
> > +                           clock-names = "qspi_en", "qspi";
> > +                           status = "disabled";
> > +                   };
> > +
> >                     sdma: sdma@30bd0000 {
> >                             compatible = "fsl,imx7d-sdma",
> > "fsl,imx35-sdma";
> >                             reg = <0x30bd0000 0x10000>;
> 
> 

-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |

Reply via email to