The thermal zone uses spmi-temp-alarm as sensor. The trip points
correspond to stage 1 and 2 temperatures. Stage 2 shutdown is disabled,
instead the stage 2 temperature is configured as critical trip point to
allow for an ordely shutdown.

Without an IIO input the sensor only reports a limited number of
temperatures:

- 37°C for temperatures below 105°C
- 107°C for temperatures >= 105°C and < 125°C
- 127°C for temperatures >= 125°C

Signed-off-by: Matthias Kaehlcke <[email protected]>
---
Changes in v4:
- updated trip point temperatures to match stage 1 and 2 ones
- disabled stage 2 shutdown
- updated commit message

Changes in v3:
- moved 'thermal-zones' node to the beginning of the .dtsi

Changes in v2:
- defined 'thermal-zones' node in pm8998.dtsi instead of using a label
  to refer to it
- use 105°C hardware trip point as critical trip point
- reduced number of trip points to 2
- lowered temperature of passive trip point
- updated trip point names and added labels
- updated commit message
---
 arch/arm64/boot/dts/qcom/pm8998.dtsi | 26 ++++++++++++++++++++++++++
 1 file changed, 26 insertions(+)

diff --git a/arch/arm64/boot/dts/qcom/pm8998.dtsi 
b/arch/arm64/boot/dts/qcom/pm8998.dtsi
index 7eea94701b23..3bb179b85a44 100644
--- a/arch/arm64/boot/dts/qcom/pm8998.dtsi
+++ b/arch/arm64/boot/dts/qcom/pm8998.dtsi
@@ -3,6 +3,31 @@
 
 #include <dt-bindings/spmi/spmi.h>
 #include <dt-bindings/interrupt-controller/irq.h>
+#include <dt-bindings/thermal/thermal.h>
+
+/ {
+       thermal-zones {
+               pm8998 {
+                       polling-delay-passive = <250>;
+                       polling-delay = <1000>;
+
+                       thermal-sensors = <&pm8998_temp>;
+
+                       trips {
+                               pm8998_alert0: pm8998-alert0 {
+                                       temperature = <105000>;
+                                       hysteresis = <2000>;
+                                       type = "passive";
+                               };
+                               pm8998_crit: pm8998-crit {
+                                       temperature = <125000>;
+                                       hysteresis = <2000>;
+                                       type = "critical";
+                               };
+                       };
+               };
+       };
+};
 
 &spmi_bus {
        pm8998_lsid0: pmic@0 {
@@ -15,6 +40,7 @@
                        compatible = "qcom,spmi-temp-alarm";
                        reg = <0x2400>;
                        interrupts = <0x0 0x24 0x0 IRQ_TYPE_EDGE_RISING>;
+                       stage2-shutdown-disabled;
                        #thermal-sensor-cells = <0>;
                };
 
-- 
2.18.0.203.gfac676dfb9-goog