Hi,

On Mar 26, 2024 at 10:16:14 +0100, Vincent Guittot wrote:
> arch_update_thermal_pressure() aims to update fast changing signal which
> should be averaged using PELT filtering before being provided to the
> scheduler which can't make smart use of fast changing signal.
> cpufreq now provides the maximum freq_qos pressure on the capacity to the
> scheduler, which includes cpufreq cooling device. Remove the call to
> arch_update_thermal_pressure() in cpufreq cooling device as this is
> handled by cpufreq_get_pressure().
> 
> Signed-off-by: Vincent Guittot <[email protected]>
> Reviewed-by: Lukasz Luba <[email protected]>
> Acked-by: Viresh Kumar <[email protected]>
> Tested-by: Lukasz Luba <[email protected]>
> ---

Makes sense,
Reviewed-by: Dhruva Gole <[email protected]>


-- 
Best regards,
Dhruva