In some cases, e.g. when TRNG is not properly configured,
the RNG module could issue a "Hardware error" at runtime.

"Continuos check" error is emitted when some of the BISTs fail.

Signed-off-by: Horia Geantă <horia.gea...@freescale.com>
Signed-off-by: Horia Geantă <horia.gea...@nxp.com>
---
 drivers/crypto/caam/error.c | 3 +++
 1 file changed, 3 insertions(+)

diff --git a/drivers/crypto/caam/error.c b/drivers/crypto/caam/error.c
index 17c6108b6d41..72db90176b1a 100644
--- a/drivers/crypto/caam/error.c
+++ b/drivers/crypto/caam/error.c
@@ -212,6 +212,9 @@ static const char * const rng_err_id_list[] = {
        "Prediction resistance and test request",
        "Uninstantiate",
        "Secure key generation",
+       "",
+       "Hardware error",
+       "Continuous check"
 };
 
 static int report_ccb_status(struct device *jrdev, const u32 status,
-- 
2.17.1