Public bug reported:

[Impact]
For some TGL platform, connect with the external monitor on the docking 
station(SC),
after cold/warm boot, the external monitor can't output the video and need to 
hotplug the docking station.

[Fix]
On the link-training phase, Wait longer during the clock recovery.

[test]
With the patch, The TGL-machine connect with the external monitor on docking 
station(SC) and
can output the video to the external monitor on docking station after cold/warm 
boot.

[Regression Potential]
Medium, it may not the root cause.

** Affects: hwe-next
     Importance: Undecided
         Status: New

** Affects: linux-oem-5.6 (Ubuntu)
     Importance: Undecided
         Status: New

** Affects: linux-oem-5.6 (Ubuntu Focal)
     Importance: Undecided
     Assignee: koba (kobako)
         Status: In Progress


** Tags: oem-priority originate-from-1892304 somerville

** Also affects: linux-oem-5.6 (Ubuntu)
   Importance: Undecided
       Status: New

** No longer affects: hwe-next

** Also affects: linux-oem-5.6 (Ubuntu Focal)
   Importance: Undecided
       Status: New

** Changed in: linux-oem-5.6 (Ubuntu Focal)
     Assignee: (unassigned) => koba (kobako)

** Changed in: linux-oem-5.6 (Ubuntu Focal)
       Status: New => In Progress

** Tags added: oem-priority originate-from-1892304 somerville

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux-oem-5.6 in Ubuntu.
https://bugs.launchpad.net/bugs/1902861

Title:
  drm/i915/dp_mst -  wait longer during the clock recovery for Display
  port

Status in HWE Next:
  New
Status in linux-oem-5.6 package in Ubuntu:
  New
Status in linux-oem-5.6 source package in Focal:
  In Progress

Bug description:
  [Impact]
  For some TGL platform, connect with the external monitor on the docking 
station(SC),
  after cold/warm boot, the external monitor can't output the video and need to 
hotplug the docking station.

  [Fix]
  On the link-training phase, Wait longer during the clock recovery.

  [test]
  With the patch, The TGL-machine connect with the external monitor on docking 
station(SC) and
  can output the video to the external monitor on docking station after 
cold/warm boot.

  [Regression Potential]
  Medium, it may not the root cause.

To manage notifications about this bug go to:
https://bugs.launchpad.net/hwe-next/+bug/1902861/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to     : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to