https://bugs.kde.org/show_bug.cgi?id=494324

Harald Sitter <sit...@kde.org> changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
      Latest Commit|                            |https://invent.kde.org/plas
                   |                            |ma/plasma-pa/-/commit/e6c65
                   |                            |46e0c7b1dc36d7f39e59f702483
                   |                            |d8fbc744
         Resolution|---                         |FIXED
             Status|ASSIGNED                    |RESOLVED

--- Comment #9 from Harald Sitter <sit...@kde.org> ---
Git commit e6c6546e0c7b1dc36d7f39e59f702483d8fbc744 by Harald Sitter.
Committed on 17/10/2024 at 13:11.
Pushed by sitter into branch 'master'.

fix text display for auto_null device

the device has no port so the currentPort text choice ended in nothing
but a warning. instead fall back to the default button text, the same
source used for the tooltip

M  +7    -1    src/kcm/ui/DeviceListItem.qml

https://invent.kde.org/plasma/plasma-pa/-/commit/e6c6546e0c7b1dc36d7f39e59f702483d8fbc744

-- 