https://bugs.kde.org/show_bug.cgi?id=490675
--- Comment #5 from Thomas Berger <l...@lokis-chaos.de> --- (In reply to Jiri Palecek from comment #3) > Yeah, that would be nice, but there would need to be a reliable way to > assign the sensors to the individual cpus. After further thoughts, i don't think this scales well on user side. Having 48 Temperature values for 4 DIEs, this will most likely get very confusing. I understand that there is the wish to keep the behavior identical across different systems with different CPU types, but AMD works differently, and especially on workstations with a high CPU count, having 4 clearly defined values instead of 12x4 may make more sense. > Just out of curiosity, could you post the output of > > grep -e . -r /sys/bus/pci/devices/0000\:00\:{18,19,1a,1b}.3/ See attachment. > Also, I wonder what are the Tccd* temperatures. Why are they only 3? And why > are they so high? >From my understanding, those are the Tctl temperature of the other 3 dies. -- You are receiving this mail because: You are watching all bug changes.