https://bugs.kde.org/show_bug.cgi?id=483689
Bug ID: 483689 Summary: invisible text in widget settings Classification: Plasma Product: plasmashell Version: 6.0.2 Platform: Neon OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: System Monitor Assignee: plasma-b...@kde.org Reporter: s_chriscoll...@hotmail.com CC: ahiems...@heimr.nl, notm...@gmail.com Target Milestone: 1.0 SUMMARY The contents of some text fields in the settings for the system monitor widgets is sometimes invisible. The only way to see the text is by selecting it with the mouse cursor. See attached video. STEPS TO REPRODUCE 1. Add a system monitor widget to the desktop (e.g., "Memory Usage") 2. Go into the settings for the widget and look through the various pages. OBSERVED RESULT Several of the text input fields appear blank, but actually contain invisible text. In the example of the "Memory Usage" widget with default settings, this affects the "Start from Angle" and "Total Pie Angle" fields on the "Pie Chart Details" page, and if you click the edit icon on any of the sensors on the "Sensors Details" page, the resulting text box will also contain invisible text. EXPECTED RESULT All of the text should be visible. SOFTWARE/OS VERSIONS Linux: KDE neon 6.0 User Edition KDE Plasma Version: 6.0.2 KDE Frameworks Version: 6.0.0 Qt Version: 6.6.2 -- You are receiving this mail because: You are watching all bug changes.