https://bugs.kde.org/show_bug.cgi?id=483260
Bug ID: 483260 Summary: Incorrect numbering sequence when saving screenshots. Classification: Applications Product: Spectacle Version: 24.02.0 Platform: Arch Linux OS: Linux Status: REPORTED Severity: minor Priority: NOR Component: General Assignee: noaha...@gmail.com Reporter: jeffgilali...@gmail.com CC: k...@david-redondo.de Target Milestone: --- Created attachment 166967 --> https://bugs.kde.org/attachment.cgi?id=166967&action=edit Screenshot of the observed result. SUMMARY Incorrect numbering sequence when using the Sequential numbering placeholder (Configure > Image Saving > Filename:) STEPS TO REPRODUCE 1. Go to Configure > Image Saving 2. Add "Test_<#>" in the Filename: input box 3. Empty the save location. 4. Take a couple of screenshots. I used the same steps with Test_<##> and Test_<###> OBSERVED RESULT Test_<#> Test_1.png Test_2.png Test_2-1.png Test_2-2.png Test_2-3.png Test_2-4.png Test_<##> Test_01.png Test_03.png Test_03-1.png Test_03-2.png Test_03-3.png Test_03-4.png Test_<###> Test_001.png Test_004.png Test_004-1.png Test_004-2.png Test_004-3.png Test_004-4.png EXPECTED RESULT Test_<#> Test_1.png Test_2.png Test_3.png Test_4.png Test_5.png Test_6.png Test_<##> Test_01.png Test_02.png Test_03.png Test_04.png Test_05.png Test_06.png Test_<###> Test_001.png Test_002.png Test_003.png Test_004.png Test_005.png Test_006.png SOFTWARE/OS VERSIONS Windows: macOS: Linux/KDE Plasma: EndeavourOS (Arch) (available in About System) KDE Plasma Version: 6.0.1 KDE Frameworks Version: 6.0.0 Qt Version: 6.6.2 -- You are receiving this mail because: You are watching all bug changes.