https://bugs.kde.org/show_bug.cgi?id=476037
Bug ID: 476037 Summary: external monitor disabled temporarily upon DPMS on Classification: Plasma Product: plasmashell Version: 5.27.8 Platform: openSUSE OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: Session Management Assignee: plasma-b...@kde.org Reporter: jirisl...@gmail.com Target Milestone: 1.0 SUMMARY If both monitors: > Output: 1 eDP-1 enabled connected priority 1 Panel Modes: 0:1920x1200@60*! > 1:1920x1200@50 2:1920x1200@48 3:1920x1080@60 4:1600x1200@60 5:1680x1050@60 > 6:1280x1024@60 7:1440x900@60 8:1280x800@60 9:1280x720@60 10:1024x768@60 > 11:800x600@60 12:640x480@60 13:1600x1200@60 14:1280x1024@60 15:1024x768@60 > 16:1920x1200@60 17:1280x800@60 18:1920x1080@60 19:1600x900@60 20:1368x768@60 > 21:1280x720@60 Geometry: 489,1440 1536x960 Scale: 1.25 Rotation: 1 Overscan: > 0 Vrr: Automatic RgbRange: unknown > Output: 2 DP-7 enabled connected priority 2 DisplayPort Modes: > 0:3840x2160@60*! 1:3840x2160@60 2:3840x2160@60 3:3840x2160@50 4:3840x2160@30 > 5:3840x2160@30 6:3840x2160@30 7:2560x1440@60 8:1920x1080@60 9:1920x1080@60 > 10:1920x1080@60 11:1920x1080@50 12:1920x1080@50 13:1680x1050@60 > 14:1600x900@60 15:1280x1024@75 16:1280x1024@60 17:1440x900@60 18:1280x800@60 > 19:1152x864@75 20:1280x720@60 21:1280x720@60 22:1280x720@60 23:1280x720@50 > 24:1024x768@75 25:1024x768@70 26:1024x768@60 27:832x624@75 28:800x600@75 > 29:800x600@72 30:800x600@60 31:800x600@56 32:720x576@50 33:720x480@60 > 34:720x480@60 35:640x480@75 36:640x480@73 37:640x480@67 38:640x480@60 > 39:640x480@60 40:720x400@70 41:1600x1200@60 42:1280x1024@60 43:1024x768@60 > 44:2560x1600@60 45:1920x1200@60 46:1280x800@60 47:3840x2160@60 > 48:3200x1800@60 49:2880x1620@60 50:2560x1440@60 51:1920x1080@60 > 52:1600x900@60 53:1368x768@60 54:1280x720@60 Geometry: 0,0 2560x1440 Scale: > 1.5 Rotation: 1 Overscan: 0 Vrr: incapable RgbRange: unknown go to DPMS off due to inactivity, waking DP-7 up takes so long, that windows are moved to eDP-1 temporarily for a second or two. Then again, all windows are restored to DP-7. STEPS TO REPRODUCE 1. be inactive 2. monitors go to sleep 3. move mouse 4. internal monitor on eDP-1 resumes quickly 5. windows from original DP-7 are moved to eDP-1 6. monitor on DP-7 resumes only now 7. windows are restored to DP-7 OBSERVED RESULT windows are moved back and forth EXPECTED RESULT it is wait for the monitor to appear. Maybe to low timeout is set? SOFTWARE/OS VERSIONS Operating System: openSUSE Tumbleweed 20231022 KDE Plasma Version: 5.27.8 KDE Frameworks Version: 5.111.0 Qt Version: 5.15.11 Kernel Version: 6.5.9-rc1-1.ga138c10-default (64-bit) Graphics Platform: Wayland Processors: 16 × AMD Ryzen 7 PRO 6850U with Radeon Graphics Memory: 29.9 GiB of RAM Graphics Processor: AMD Radeon Graphics Manufacturer: LENOVO Product Name: 21CRS0K83K System Version: ThinkPad T14s Gen 3 -- You are receiving this mail because: You are watching all bug changes.