https://bugs.kde.org/show_bug.cgi?id=470632

Nate Graham <n...@kde.org> changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
      Latest Commit|https://invent.kde.org/plas |https://invent.kde.org/plas
                   |ma/plasma-workspace/-/commi |ma/plasma-workspace/-/commi
                   |t/dfe7545b04bec092ee28299f9 |t/98f39bbce64e526679f7c9195
                   |88508c38321961b             |f1282fa972dedaa

--- Comment #4 from Nate Graham <n...@kde.org> ---
Git commit 98f39bbce64e526679f7c9195f1282fa972dedaa by Nate Graham.
Committed on 05/06/2023 at 22:56.
Pushed by ngraham into branch 'Plasma/5.27'.

applets/batterymonitor: Fix wrong tooltip when plugged in but discharging

In this case, the tooltip subtext line would still say "X time until
fully charged" because it was not checking to make sure that the battery
was in fact actually charging. This commit makes it do so, so now it
will fall through to the next condition that displays text suitable for
a battery that's discharging.
FIXED-IN: 5.27.6


(cherry picked from commit dfe7545b04bec092ee28299f988508c38321961b)

M  +1    -1    applets/batterymonitor/package/contents/ui/main.qml

https://invent.kde.org/plasma/plasma-workspace/-/commit/98f39bbce64e526679f7c9195f1282fa972dedaa

-- 