https://bugs.kde.org/show_bug.cgi?id=466238
--- Comment #5 from Rune <rune.fritzs...@web.de> --- (In reply to Rune from comment #0) > SUMMARY > > Having multiple screens with different scaling factors in the plasma wayland > session makes it impossible to exit fullscreen video playback. The screen > that played back the video becomes unusable, the second screen works fine. > Graphical glitches can be observed on the primary screen when trying to exit > the full screen playback. > > > STEPS TO REPRODUCE > 1. Set different scaling factors on two monitors. > 2. Start playing back video in full screen mode (tried firefox (Youtube, > Netflix) as well as VLC (local file). > 3. Try exiting the playback. > > OBSERVED RESULT > > The screen becomes unresponsive and shows graphical artifacts. > > EXPECTED RESULT > > The video playback can be exited normally. > > SOFTWARE/OS VERSIONS > Linux/KDE Plasma: Arch Linux 6.1.12-arch > (available in About System) > KDE Plasma Version: 5.27.1 > KDE Frameworks Version: 5.103.0 > Qt Version: 5.15.8 > > ADDITIONAL INFORMATION > > AMD GPU with open source drivers, though proprietary OpenGL driver is > installed. Hardware acceleration is enabled. More info: Even without mixed scaling factors, being unable to exit fullscreen is a problem. Wether it occurs or not seems to be linked to the time spent in fullscreen mode, It also does only happen with video playback, not when playing e.g. video games in full screen. -- You are receiving this mail because: You are watching all bug changes.