https://bugs.kde.org/show_bug.cgi?id=466277
Bug ID: 466277 Summary: USB sensor devices name changes causes sensors not to be found on nearly every boot Classification: Plasma Product: plasma-systemmonitor Version: 5.27.1 Platform: Other OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: general Assignee: ksysguard-b...@kde.org Reporter: ville.aa...@gmail.com CC: ahiems...@heimr.nl, plasma-b...@kde.org Target Milestone: --- Plasma System Monitor does not find the sensors on a USB monitoring device after a reboot. This is because the name of the device in lmsensors changes every boot. It has a suffix in case of USB devices of the form -hid-X-Y (or similar), where X and Y change. In my case, the device is a Corsair Commander Pro. Plasma System Monitor could be more intelligent in finding the right device. The devices have a name node in /sys/class/hwmon/hwmon?/name, but I'm not sure if this is exposed to System Monitor (does it use libsensors?). This bug is very similar to the one I've reported against ksysguard: https://bugs.kde.org/show_bug.cgi?id=438031 STEPS TO REPRODUCE 1. Add sensors from a USB sensoring device into Plasma System Monitor 2. Reboot 3. Re-open Plasma System Monitor. OBSERVED RESULT More likely than not, the sensors have not been found (retry from step 2 if the bug didn't trigger by chance). EXPECTED RESULT The sensors should be found. SOFTWARE/OS VERSIONS Windows: macOS: Linux/KDE Plasma: (available in About System) KDE Plasma Version: KDE Frameworks Version: Qt Version: -- You are receiving this mail because: You are watching all bug changes.