https://bugs.kde.org/show_bug.cgi?id=465026

--- Comment #6 from nielsrackw...@googlemail.com ---
After a bit more investigation I realize that the Optical Train dialog not
showing seems to be related to whether port selection is enabled or disabled in
the profile. If port selection is enabled - as seems to be the default for new
profiles - then the Optical Train dialog will not show for me, thus I can't
assign any connected devices to be used with ECOS. Also, while port selection
is enabled in a new profile, the port selection dialog in my case does not
show.

In contrast to my initial thought it seems to be irrelevant whether the device
connections are local or remote. Some steps to replicate with KStars 3.6.3 on
OSX based on simulators:

1) Create new profile with local INDI, port selection is ENABLED,
2) Add simulators for mount and CCD,
3) Connect devices (simulators) - here, Optical Train dialog will not show,
thus I can't assign simulators to an optical train. Also, neither the port
selection dialog shows. 
4) Switch into ECOS CCD tab. No optical train and hence no CCD can be selected,
thus no frame can be captured although simulators are connected. 

5) Create new profile with local INDI and disable port selection,
6) Add simulators for mount and CCD,
7) Connect devices (simulators) - now Optical train dialog will show and I can
assign simulators to an optical train,
8) Now when switching into ECOS CCD tab I can select and optical train and the
CCD simulator and capture a frame.

A few screen shots are attached.

-- 
You are receiving this mail because:
You are watching all bug changes.

Reply via email to