https://bugs.kde.org/show_bug.cgi?id=462705

            Bug ID: 462705
           Summary: Change done in the settings of a System Monitor widget
                    while it is in edit mode is not properly applied until
                    leaving the edit mode
    Classification: Plasma
           Product: plasmashell
           Version: 5.26.4
          Platform: Archlinux
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: System Monitor
          Assignee: plasma-b...@kde.org
          Reporter: bugsefor...@gmx.com
                CC: ahiems...@heimr.nl, notm...@gmail.com
  Target Milestone: 1.0

Created attachment 154358
  --> https://bugs.kde.org/attachment.cgi?id=154358&action=edit
screenshot

STEPS TO REPRODUCE
1. open the Widgets Explorer
2. search for Individual Core Usage widget and add it to desktop
3. open the widget settings
4. while the widget settings is open, click and hold the widget until it enters
in the edit mode - let's suppose I want to resize the widget after opening its
settings
5. go back to the widget settings and change the display style to 'Horizontal
bars'
6. apply the change by clicking on 'Apply' or 'OK' buttons

OBSERVED RESULT
the sensors of the widget do not work, as seen in the attached screenshot.
When I leave the edit mode by clicking on desktop, the sensors start to work as
expected.

EXPECTED RESULT
the sensors should work immediately after the last step

SOFTWARE/OS VERSIONS
Operating System: Arch Linux
KDE Plasma Version: 5.26.4
KDE Frameworks Version: 5.100.0
Qt Version: 5.15.7
Graphics Platform: Wayland

-- 
You are receiving this mail because:
You are watching all bug changes.