Bug ID: 462560 Summary: Info Element does not connect to second curve Classification: Applications Product: LabPlot2 Version: 2.9.0 Platform: Microsoft Windows OS: Microsoft Windows Status: REPORTED Severity: normal Priority: NOR Component: general Assignee: alexander.se...@web.de Reporter: robgrueb...@gmail.com Target Milestone: --- Created attachment 154240 --> https://bugs.kde.org/attachment.cgi?id=154240&action=edit Screenshot "IS02_LPIE01.png" SUMMARY The info element always shows the values of curve 1, even if it is connected to curve 2. STEPS TO REPRODUCE 1. Start LabPlot 2. Open project IssueInfoEle.lml 3. Add an Info Element to the plot 4. In Settings Info Element: select both curves and connect to "Relative Humidity in%". OBSERVED RESULT Info element always shows the values of curve 1. See IS02_LPIE01.png EXPECTED RESULT Info element shows the values of curve 2 and possibly the values of curve 1. SOFTWARE/OS VERSIONS Win10 Pro 64 bit, German LabPlot V 2.9.0, Release build Dec 1 2022, 17:22:55; Language=English ADDITIONAL INFORMATION -- You are receiving this mail because: You are watching all bug changes.