https://bugs.kde.org/show_bug.cgi?id=450068

David Edmundson <k...@davidedmundson.co.uk> changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
                 CC|                            |k...@davidedmundson.co.uk

--- Comment #10 from David Edmundson <k...@davidedmundson.co.uk> ---
There's more useful proposal discussion on
https://invent.kde.org/plasma/plasma-workspace/-/issues/21. 

>* make plasmashell not identify connectors anymore, but only use the relative 
>position of outputs

Apparently KDE4 did that. It's an option. Though we still need to take into
account primary screens as you might plug into an external either side.

>* make plasmashell use the EDID (monitor manufacturer, name and serial number) 
>where available instead of the connector name
>* make KWin set the output name to an actual output name, instead of using 
>connector names

We don't want every new monitor/projector/etc to have it's own containment. 

Our end goal is to re-used the second containment for each second screen but
have 3 be consistent when in a static setup. With this we'd still need
screenpool to create a mapping, still get conflicts and still be swapping about
completely randomly.
It'll solve some bugs for sure, but introduce as many. 

My preferred solution is to introduce secondary/tertiary screen concept into
kscreen; then we're building on the system we have for primary instead of
always trying to invent 2 competing systems at once interleaving.

-- 
You are receiving this mail because:
You are watching all bug changes.