https://bugs.kde.org/show_bug.cgi?id=450068
David Edmundson <k...@davidedmundson.co.uk> changed: What |Removed |Added ---------------------------------------------------------------------------- CC| |k...@davidedmundson.co.uk --- Comment #10 from David Edmundson <k...@davidedmundson.co.uk> --- There's more useful proposal discussion on https://invent.kde.org/plasma/plasma-workspace/-/issues/21. >* make plasmashell not identify connectors anymore, but only use the relative >position of outputs Apparently KDE4 did that. It's an option. Though we still need to take into account primary screens as you might plug into an external either side. >* make plasmashell use the EDID (monitor manufacturer, name and serial number) >where available instead of the connector name >* make KWin set the output name to an actual output name, instead of using >connector names We don't want every new monitor/projector/etc to have it's own containment. Our end goal is to re-used the second containment for each second screen but have 3 be consistent when in a static setup. With this we'd still need screenpool to create a mapping, still get conflicts and still be swapping about completely randomly. It'll solve some bugs for sure, but introduce as many. My preferred solution is to introduce secondary/tertiary screen concept into kscreen; then we're building on the system we have for primary instead of always trying to invent 2 competing systems at once interleaving. -- You are receiving this mail because: You are watching all bug changes.