https://bugs.kde.org/show_bug.cgi?id=366549
Bug ID: 366549 Summary: plasmashell stops updating panel after suspend/resume or locked screen Product: plasmashell Version: 5.7.3 Platform: Archlinux Packages OS: Linux Status: UNCONFIRMED Severity: normal Priority: NOR Component: general Assignee: k...@davidedmundson.co.uk Reporter: th...@ginkel.com CC: bhus...@gmail.com, plasma-b...@kde.org Hello everyone, I'm aware of #341951, which is marked as fixed, though. As I am hitting a very similar bug with current Plasma 5, I am opening this new issue. Feel free to resolve it as duplicate and reopen #341951 if that makes more sense. I am using Plasma 5.7.3 (Breeze Dark theme) with X.org Intel drivers in DRI2 mode. Kwin compositing is configured to use OpenGL 2.0. At regular intervals, most easily triggered by a suspend/resume cycle or screen lock operation my plasma panel stops updating, i.e., the clock freezes and the task manager settings no longer reflect the currently running applications. The panel remains responsive, though, i.e., clicking on the clock opens the calendar. Restarting plasmashell resolves the problem until it eventually surfaces again. I tried getting a backtrace from plasmashell, but connecting gdb and issuing the 'backtrace' command just produces: (gdb) backtrace No stack. Any ideas how to debug this further are much appreciated! Thanks! P.S.: xf86-video-intel version 1:2.99.917+691+ga77397a-1 Reproducible: Always Steps to Reproduce: 1. Log in to KDE Plasma session 2. Suspend/resume 3. Notice that the clock stops updating -- You are receiving this mail because: You are watching all bug changes.