https://bugs.kde.org/show_bug.cgi?id=447847

            Bug ID: 447847
           Summary: Display style 'Grid', unnecessary entries
           Product: plasma-systemmonitor
           Version: 5.23.4
          Platform: Other
                OS: Linux
            Status: REPORTED
          Severity: minor
          Priority: NOR
         Component: general
          Assignee: ksysguard-b...@kde.org
          Reporter: stefan....@pm.me
                CC: ahiems...@heimr.nl, plasma-b...@kde.org
  Target Milestone: ---

SUMMARY
When using the display style 'Grid', below the field 'Number of columns',
another selection field (combo box) 'Display style' is displayed. This contains
the same entries as the primary one, not all of which make sense here. IMO only
'Bar Chart', 'Horizontal Bars', 'Line Chart', 'Pie Chart' and 'Text Only' are
applicable here. The values 'Applications Table' and 'Process Table' show one
application/process table per selected sensor, which is not very useful. The
value 'Grid' duplicates the configuration area for grid, showing yet another
'Display Style' selection field, which can yet again be set to 'Grid', and so
forth.

STEPS TO REPRODUCE
1. Click button 'Edit Page'
2. Select a sensor for editing; example CPU Total Usage
3. Change display style to 'Grid'
4. (optional) Change the new display style that has appeared below 'Number of
Columns' to 'Grid'
5. (optional) GOTO 4

OBSERVED RESULT
Every time 'Grid' is selected, another display style field is displayed. If
Applications Table' or 'Process Table' are selected, those tables are shown for
each selected sensor instead of a sensor value.

EXPECTED RESULT
The second 'Display Style' selection should only contain values that make sense
for the grid to display.