https://bugs.kde.org/show_bug.cgi?id=442950
Bug ID: 442950 Summary: Wrong microphone icon size used in Audio Volume when it exists in plasma style Product: plasmashell Version: 5.22.90 Platform: Neon Packages OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: general Assignee: k...@davidedmundson.co.uk Reporter: doncb...@gmail.com CC: plasma-b...@kde.org Target Milestone: 1.0 Created attachment 141910 --> https://bugs.kde.org/attachment.cgi?id=141910&action=edit speakers using correct icon size while microphone uses largest SUMMARY At some point during the audio slider rework, it appears the way of selecting the appropriate icon size for the microphone mute button changed. Now, when microphone.svg is present in a plasma style's icons, the smaller icon is not used. The speakers mute button does not appear to have this problem. STEPS TO REPRODUCE 1. Apply a style with a "microphone" icon in its "icons/" directory (I used the Malice theme) 2. Run plasmashell --replace to properly update icons 3. Open Audio Volume on a device with microphone enabled OBSERVED RESULT The microphone icon is very fuzzy and clearly not using the 16x16 version of the icon. The speakers mute button will be using its proper 16x16 version. EXPECTED RESULT The microphone icon should be the 16x16 version, just as the speakers button. SOFTWARE/OS VERSIONS Windows: macOS: Linux/KDE Plasma: (available in About System) KDE Plasma Version: 5.22.90 KDE Frameworks Version: Qt Version: ADDITIONAL INFORMATION -- You are receiving this mail because: You are watching all bug changes.