https://bugs.kde.org/show_bug.cgi?id=439459

            Bug ID: 439459
           Summary: Pressing the down arrow on the last category in any
                    sidebar causes the vertical alignment to get messed up
           Product: systemsettings
           Version: 5.22.2
          Platform: Other
                OS: Other
            Status: REPORTED
          Severity: minor
          Priority: NOR
         Component: sidebarview
          Assignee: notm...@gmail.com
          Reporter: kishor...@gmail.com
                CC: plasma-b...@kde.org
  Target Milestone: ---

Created attachment 139835
  --> https://bugs.kde.org/attachment.cgi?id=139835&action=edit
Screenshot of the broken state

SUMMARY
If the focus is on the last item in a sidebar, pressing the down arrow causes
the items to become vertically aligned to the bottom

STEPS TO REPRODUCE
1. Go to System Settings > Workspace > Startup and shutdown
2. Click in the sidebar that shows subcategories, placing the focus on the last
item (Desktop session)
3. Press down arrow (keyboard key)

OBSERVED RESULTS
Pressing 'down' when the last item in a sidebar is selected vertically aligns
everything to the bottom (see attached screenshot).

EXPECTED RESULTS
Pressing the down arrow in step 3 should do nothing.

SOFTWARE VERSIONS
Operating System: Arch Linux
KDE Plasma Version: 5.22.2
KDE Frameworks Version: 5.83.0
Qt Version: 5.15.2
Kernel Version: 5.10.47-1-lts (64-bit)

ADDITIONAL INFORMATION
Seems to be a general bug with the sidebar. Also reproducible in Settings >
Workspace > Search

-- 
You are receiving this mail because:
You are watching all bug changes.

Reply via email to