https://bugs.kde.org/show_bug.cgi?id=437310

            Bug ID: 437310
           Summary: System monitor does not allow for negative values in
                    ring charts
           Product: plasma-systemmonitor
           Version: 5.21.5
          Platform: Fedora RPMs
                OS: Linux
            Status: REPORTED
          Severity: major
          Priority: NOR
         Component: general
          Assignee: ksysguard-b...@kde.org
          Reporter: kitt...@gmail.com
                CC: ahiems...@heimr.nl, plasma-b...@kde.org
  Target Milestone: ---

Created attachment 138543
  --> https://bugs.kde.org/attachment.cgi?id=138543&action=edit
See the Rate chart

SUMMARY
I've added a ring chart for my battery's chargin rate, but there's no way of
mapping it to also negative values.

STEPS TO REPRODUCE
1. add a ring chart for a sensor that can read negative values
2. set the right domain for the sensor or either leave auto
3. wait for negative values

OBSERVED RESULT
ring starts showing a very casual behavior, not even linear wrt values.

EXPECTED RESULT
on a very basic level, it should not matter whether readings are negatively or
positively valued. once a domain is entered, graph should divide currently set
angular domain by sensor domain length, and add the lowest bound as an offset.
Or even better, it should recognize signed domains and have the ring go
clockwise for positive values and ccwise for negative ones, starting from 0.

SOFTWARE/OS VERSIONS
Linux/KDE Plasma: 5.11.20-300.fc34.x86_64
(available in About System)
KDE Plasma Version: 5.21
KDE Frameworks Version: 5.81
Qt Version: 5.15.2

-- 
You are receiving this mail because:
You are watching all bug changes.

Reply via email to