https://bugs.kde.org/show_bug.cgi?id=431486

            Bug ID: 431486
           Summary: When changing the scaling back and forth some elements
                    in the "screen kcm" become blurry
           Product: kwin
           Version: 5.20.5
          Platform: Other
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: general
          Assignee: kwin-bugs-n...@kde.org
          Reporter: pos...@posteo.eu
  Target Milestone: ---

Created attachment 134769
  --> https://bugs.kde.org/attachment.cgi?id=134769&action=edit
Screenshot with blurry elements

STEPS TO REPRODUCE
1. Start a plasma wayland session
2. Go to the system settings, screen kcm
3. Select 200% scaling and click apply
4. Select 100% scaling and click apply
5. Select 200% scaling and click apply
6. (optional after step 4 or 5) move the scaling slider

OBSERVED RESULT

The text in the input field for the scaling as well as the text in the combobox
of the refresh rate become blurry.
On another system, the text in the resolution combobox was blurry instead.

If you go to another KCM and come back, everything looks fine again.


SOFTWARE/OS VERSIONS
Operating System: Manjaro Linux
KDE Plasma Version: 5.20.4
KDE Frameworks Version: 5.77.0
Qt Version: 5.15.2
Graphics Processor: Mesa IntelĀ® HD Graphics 620

ADDITIONAL INFORMATION
HiDPI, Multi-Monitor (also happened on a single screen setup/different system)

-- 