https://bugs.kde.org/show_bug.cgi?id=400514

            Bug ID: 400514
           Summary: Ekos Flat Calibration causes slew during Light
                    collection
           Product: kstars
           Version: unspecified
          Platform: Fedora RPMs
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: general
          Assignee: mutla...@ikarustech.com
          Reporter: txgib...@twc.com
  Target Milestone: ---

Created attachment 116003
  --> https://bugs.kde.org/attachment.cgi?id=116003&action=edit
log file

SUMMARY
System: Mach1, ASI071 oag:ASI120-s




STEPS TO REPRODUCE
1. 
Collect Flats using calibrate set to "The Wall" AZ: 280 00 00, ALT: 01 00 00. 

2. 
Collect Lights by using mount control goto to select a target, use of solver,
start guding, then in CCD start to collect a sequence of lights at the solved
position.

3. 
The mount slews to the wall position established for flats.

OBSERVED RESULT

Selecting flats and setting the calibration from wall to manual allows lights
to be captured but the manual setting does not persist. The next time KStars is
started calibration reverts to the wall again.

Subsequent collection of lights fails. This is the case even though flats were
not revisited and calibrate is grayed out.

EXPECTED RESULT

There is no interaction between the Flat enabled calibrate options and the
collection of Light frames.

The Flat calibration selections persist across restarts once changed.

SOFTWARE VERSIONS
kstars-bleeding.x86_64  3.0.0-16.3 
libindi-bleeding.x86_64 1.7.5-18.1 
(available in About System)
KDE Plasma Version: 
KDE Frameworks Version: 
Qt Version: 

ADDITIONAL INFORMATION
log attached thought to include the behavior.

-- 