https://bugs.kde.org/show_bug.cgi?id=516422
Bug ID: 516422
Summary: [REG] Panel popups/tooltips and notifications have
wrong position when additional monitor is
(dis)connected
Classification: Plasma
Product: plasmashell
Version First 6.6.0
Reported In:
Platform: Other
OS: Linux
Status: REPORTED
Severity: normal
Priority: NOR
Component: general
Assignee: [email protected]
Reporter: [email protected]
CC: [email protected]
Target Milestone: 1.0
SUMMARY
Panel popups/tooltips and notifications have wrong position when additional
monitor is connected/disconnected or monitors are reordered.
STEPS TO REPRODUCE
1. Launch plasmashell with one monitor.
2. Connect second monitor (as non-primary, position it on the left of the first
primary monitor).
3. Open notification or tooltip (hover icon or window on taskbar).
OBSERVED RESULT
Panel tooltips are on the bottom-left corner of the primary screen.
Notifications are on the top-left corner of another screen. Popups on panel has
also wrong position (including context menu and kickoff).
OSD (e.g. volume indicator) and tooltips on desktop icons are OK.
`plasmashell --replace` "fixes" the issue.
EXPECTED RESULT
Tooltips are in correct positions.
SOFTWARE/OS VERSIONS
KDE Plasma Version: 6.6.0
KDE Frameworks Version: 6.23.0
Qt Version: 6.10.2
ADDITIONAL INFORMATION
Linux/Wayland
Regression from 6.5.
--
You are receiving this mail because:
You are watching all bug changes.