https://bugs.kde.org/show_bug.cgi?id=512044

            Bug ID: 512044
           Summary: Initialization failed: Live: No column modes set
    Classification: Applications
           Product: LabPlot2
      Version First 2.12.0
       Reported In:
          Platform: Other
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: general
          Assignee: [email protected]
          Reporter: [email protected]
  Target Milestone: ---

Created attachment 186754
  --> https://bugs.kde.org/attachment.cgi?id=186754&action=edit
Error message

SUMMARY
When adding a live data source from a serial port, the "Data Format" tab is
greyed out and the message "initialization failed: Live: No column modes set"
appears at the bottom. I am unable to get data from a serial device.

STEPS TO REPRODUCE
1. Plug a serial device outputting  comma separated data into a USB port.
2. Create a new Labplot project
3. Add a new live data source from a serial port
4. Select the correct port and baud rate
5. Select ASCII Data type

OBSERVED RESULT
Unable to edit the Data Format

EXPECTED RESULT
Able to edit the Data Format

SOFTWARE/OS VERSIONS
Operating System: Arch Linux 
KDE Plasma Version: 6.5.2
KDE Frameworks Version: 6.19.0
Qt Version: 6.10.0
Kernel Version: 6.17.7-arch1-1 (64-bit)
Graphics Platform: Wayland
Processors: 32 × 13th Gen Intel® Core™ i9-13900HX
Memory: 32 GiB of RAM (31.1 GiB usable)
Graphics Processor: NVIDIA GeForce RTX 4090 Laptop GPU

ADDITIONAL INFORMATION

-- 
You are receiving this mail because:
You are watching all bug changes.