--- Comment #4 from Jörg Habenicht <[email protected]> ---
Hello Nate,
sorry, I can not figure it out. Can you give me one more hint?
xosview is a very old app back from the 90s, it got no connection to kde or
plasma. I installed version 1.23 and 1.22 with the same result. xosview is
started twice during the login autostart. Version 1.22 was dumped during
plasma5, so most likely I used that version 1.22 flawless during plasma5. With
plasma5 xosview only started once during autostart. What gives?

I tested xterm as another X app. But xterm only starts once during the login
autostart.
So yes, plasma6 does not seem to start x apps twice. But the xosview version
(1.22) I used with plasma5 (started only once) now starts twice with plasma6.
So where is the error in the logical analysis?

Do you got a hint where to look further?
Thanks

-- 