https://bugs.kde.org/show_bug.cgi?id=510687

            Bug ID: 510687
           Summary: Displayed as ‘text only’ no longer works
    Classification: Plasma
           Product: plasmashell
      Version First 6.4.5
       Reported In:
          Platform: openSUSE
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: System Monitor widgets
          Assignee: [email protected]
          Reporter: [email protected]
                CC: [email protected], [email protected]
  Target Milestone: 1.0

Created attachment 185841
  --> https://bugs.kde.org/attachment.cgi?id=185841&action=edit
normal:expected result and before Qt 6.10

After the update to Qt 6.10, the system monitor widget no longer shows any data
when 'text only' style is used. If the sensors are used in combination with
another style, the data is shown, changing when back to "text only" the data is
shown but will disappears after the next reboot/login. Sensors I use are
cpu/gpu temps, fan speeds, system load, etx, please see attached pics.


STEPS TO REPRODUCE
1. Use text only style - no data is shown
2. Use any other style e.g. with a diagram - data is shown
3. 

OBSERVED RESULT
The widget is empty, no sensor/data is shown

EXPECTED RESULT
Display of the sensors with the relevant data

SOFTWARE/OS VERSIONS
Linux/KDE Plasma: openSUSE Tumbleweed 
KDE Plasma Version: 6.4.5
KDE Frameworks Version: 6.19.0
Qt Version: 6.10.0

ADDITIONAL INFORMATION

-- 
You are receiving this mail because:
You are watching all bug changes.