https://bugs.kde.org/show_bug.cgi?id=500618
Arjen Hiemstra <ahiems...@heimr.nl> changed: What |Removed |Added ---------------------------------------------------------------------------- Version|6.3.1 |6.12.0 CC| |k...@davidedmundson.co.uk, | |noaha...@gmail.com, | |notm...@gmail.com Assignee|ksysguard-b...@kde.org |kdelibs-b...@kde.org Product|plasma-systemmonitor |frameworks-qqc2-desktop-sty | |le Component|general |general --- Comment #2 from Arjen Hiemstra <ahiems...@heimr.nl> --- It looks like a binding loop, where if you hit the sizes just right it will continuously update to account for scrollbars - then realise the scrollbars aren't needed and the entire cycle starts again. Fixing this will need to be done in qqc2-desktop-style however, as system monitor just uses a ScrollView here. So moving this there. -- You are receiving this mail because: You are watching all bug changes.