https://bugs.kde.org/show_bug.cgi?id=500618

Arjen Hiemstra <ahiems...@heimr.nl> changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
            Version|6.3.1                       |6.12.0
                 CC|                            |k...@davidedmundson.co.uk,
                   |                            |noaha...@gmail.com,
                   |                            |notm...@gmail.com
           Assignee|ksysguard-b...@kde.org      |kdelibs-b...@kde.org
            Product|plasma-systemmonitor        |frameworks-qqc2-desktop-sty
                   |                            |le
          Component|general                     |general

--- Comment #2 from Arjen Hiemstra <ahiems...@heimr.nl> ---
It looks like a binding loop, where if you hit the sizes just right it will
continuously update to account for scrollbars - then realise the scrollbars
aren't needed and the entire cycle starts again.

Fixing this will need to be done in qqc2-desktop-style however, as system
monitor just uses a ScrollView here. So moving this there.

-- 