https://bugs.kde.org/show_bug.cgi?id=501187
Bug ID: 501187 Summary: Toolbar disappears when moving full screen window to different display Classification: Applications Product: krdc Version: 24.12.3 Platform: Arch Linux OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: general Assignee: uwol...@kde.org Reporter: irosin...@outlook.com Target Milestone: --- SUMMARY When KRDC is in fullscreen, and I move the fullscreen window to a different display (e.g. with Meta+Shift+Arrow key), the toolbar no longer appears at the top of the screen. STEPS TO REPRODUCE Prerequisite: Have multiple monitors 1. Open KRDC. 2. Click the Full Screen button. 3. Press Meta+Shift+Arrow key (or your appropriate shortcut) to move the window to a different monitor. OBSERVED RESULT The toolbar appears at the top of the screen when pressing Full Screen. The toolbar disappears completely when moving the window to a different monitor. EXPECTED RESULT The toolbar appears at the top of the screen when pressing Full Screen. The toolbar moves to the top of the different monitor when moving the window to a different monitor. SOFTWARE/OS VERSIONS Operating System: Arch Linux KDE Plasma Version: 6.3.2 KDE Frameworks Version: 6.11.0 Qt Version: 6.8.2 Kernel Version: 6.13.5-arch1-1 Graphics Platform: Wayland ADDITIONAL INFORMATION I was able to reproduce this issue on 24.12.3 and 24.12.2, but not 24.12.1. This is a particularly annoying issue due to Bug 488656--in my setup, the leftmost monitor is portrait, so the fullscreen window always appears on the portrait monitor, and once I move it to a landscape monitor I can no longer get to the toolbar (e.g. to capture keys or disconnect). -- You are receiving this mail because: You are watching all bug changes.