https://bugs.kde.org/show_bug.cgi?id=497749
Bug ID: 497749 Summary: touch broken when resolution changed Classification: Plasma Product: kwin Version: 6.2.4 Platform: Fedora RPMs OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: input Assignee: kwin-bugs-n...@kde.org Reporter: kdebuac....@porcupinefactory.org CC: duha.b...@gmail.com Target Milestone: --- SUMMARY The input area doesn't match the display area if letterboxing is used. Touching a place on the screen doesn't actually register in the touched place, but offset the farther from the middle it is. Same with digitizer pen. STEPS TO REPRODUCE 1. Change resolution from native 1920x1200 to 1920x1080. The display has now a black bar on the bottom. 2. Touch the Plasma Menu icon on the bottom left OBSERVED RESULT Probably nothing happens: actual click is above the button EXPECTED RESULT The click should be exactly on the button SOFTWARE/OS VERSIONS Linux/KDE Plasma: 6.2.4 KDE Frameworks Version: 6.9.0 Qt Version: 6.8.1 ADDITIONAL INFORMATION Wayland. This is super annoying because mirroring over multiple screens of different proportions also has other bugs. Pen calibration also doesn't fix this problem. -- You are receiving this mail because: You are watching all bug changes.