stevenzwu commented on code in PR #5967: URL: https://github.com/apache/iceberg/pull/5967#discussion_r1037812837
########## docs/flink-getting-started.md: ########## @@ -683,7 +683,47 @@ env.execute("Test Iceberg DataStream"); OVERWRITE and UPSERT can't be set together. In UPSERT mode, if the table is partitioned, the partition fields should be included in equality fields. {{< /hint >}} -## Write options +## Options +### Read options + +Flink read options are passed when configuring the FlinkSink, like this: + +``` +IcebergSource.forRowData() + .tableLoader(tableResource.tableLoader()) + .assignerFactory(new SimpleSplitAssignerFactory()) + .streaming(scanContext.isStreaming()) + .streamingStartingStrategy(scanContext.streamingStartingStrategy()) + .startSnapshotTimestamp(scanContext.startSnapshotTimestamp()) + .startSnapshotId(scanContext.startSnapshotId()) + .set("monitor-interval", "10s") + .build() +``` +For Flink SQL, read options can be passed in via SQL hints like this: +``` +SELECT * FROM tableName /*+ OPTIONS('monitor-interval'='10s') */ +... +``` Review Comment: we also need to add en example on how to set the read option via Flink config (table env). -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: issues-unsubscr...@iceberg.apache.org For queries about this service, please contact Infrastructure at: us...@infra.apache.org --------------------------------------------------------------------- To unsubscribe, e-mail: issues-unsubscr...@iceberg.apache.org For additional commands, e-mail: issues-h...@iceberg.apache.org