mxm commented on issue #17140:
URL: https://github.com/apache/iceberg/issues/17140#issuecomment-4933189818

   `StandardSinkTopologies.addGlobalCommitter` is a bit of a workaround because 
it doesn't replace the committer, but runs as post-commit. Under the hood, it 
creates an operator with parallelism 1. Unfortunately, this is only available 
for Flink 2.0 and above (we still support Flink 1.20). It could be a viable 
path.
   
   On the other hand, the current code works fine, apart from the catalog load 
issue. We already aggregate all the WriteResults and send them only to a 
committer subtask 0. So the rest of the committer subtasks never do anything. I 
would suggest to just check the subtask id in the committer and return for any 
subtasks id > 0. We should make sure to throw in case any messages ever make it 
to a subtask id > 0.
   
   What do you think?


-- 