https://issues.apache.org/jira/browse/GEODE-7940?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Barrett Oglesby updated GEODE-7940:
-----------------------------------
    Attachment: create-sender-alter-region-all-gfsh_04-01-2020.tgz

> A parallel GatewaySender stops sending events if another GatewaySender that 
> was attached to the same region is destroyed
> ------------------------------------------------------------------------------------------------------------------------
>
>                 Key: GEODE-7940
>                 URL: https://issues.apache.org/jira/browse/GEODE-7940
>             Project: Geode
>          Issue Type: Bug
>          Components: wan
>            Reporter: Barrett Oglesby
>            Priority: Major
>         Attachments: create-sender-alter-region-all-gfsh_04-01-2020.tgz
>
>
> The attached test reproduces this issue.
> It starts 3 distributed systems named ln, ny and tk.
> ny and tk each have a gateway receiver and a region defined.
> Use gfsh in ln to:
> 1. Create sender to ny
> 2. Create region with sender to ny
> 3. Start doing puts from a client (verify updates are happening in ny)
> 4. Create sender to tk
> 5. Alter region add sender to tk (verify updates are happening in tk)
> 6. Stop sender to ny
> 7. Alter region remove sender to ny
> 8. Destroy sender to ny
> Updates should stop to ny but not tk, but updates to both stop.
> The ln log contains no exceptions. The stats show events being received and 
> queued by the sender to tk. The eventQueueSize is 0, though.
> If step 8 is not done, updates continue flowing to tk.
> If the ln server is restarted, updates start flowing to tk again.



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to