Am Dienstag, 17. März 2015, 15:34:59 schrieb Dorai Sitaram: > If I set registers PO and LL and also set PS and VS, the values of PO and LL > seem to revert to the default values. It doesn't seem to matter which order I > set these registers in (all done in the preamble of the document of course). > What is a way to make all settings of these four registers stick? > thanks,--d
For me it works as expected. Suppose this input ----------------------------------------------- .nr PO 4c .nr LL 10c .nr PS 20 .nr VS 22 .LP This is a line following the settings above. This is a line following the settings above. This is a line following the settings above. This is a line following the settings above. This is a line following the settings above. This is a line following the settings above. This is a line following the settings above. ----------------------------------------------- The result is attached as PDF. Heinz
test.pdf
Description: Adobe PDF document