2016-09-01 11:55 GMT+03:00 Frank Steinmetzger <war...@gmx.de>:
> On Thu, Sep 01, 2016 at 11:44:19AM +0300, gevisz wrote:
>
>> > Some people do a full systems check (i.e. badblocks) before entrusting a
>> > drive with anything important.
>>
>> It is a good advice! I have already thought of this but I am sorry to
>> acknowledge that, since the "old good times" of MS DOS 6.22, I never did
>> this in Linux. :(
>> […]
>> So, can you, please, advice me about the program or utility that can do
>> badblocks check for me?
>
> Badblocks is part of e2fsprogs. But since you’re using USB2, this will
> really take a while. At best I get 39 MB/s out of it. Another way is a
> S.M.A.R.T. test, methinks `smartctl -t full` is the command for that. But I
> don’t know what exactly is being tested there. But it runs fully internal of
> the disk, so no USB2-bottleneck. Others may chime in if I tell fairy tales.

So far, the hard drive passed two (small) smart tests started by commands:
# smartctl -c -t short -d sat /dev/sdc
and
# smartctl -t conveyance -d sat /dev/sdc
as is indicated by
# smartctl -l selftest -d sat /dev/sdc
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.6-gentoo] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF READ SMART DATA SECTION ===
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining
LifeTime(hours)  LBA_of_first_error
# 1  Conveyance offline  Completed without error       00%         0         -
# 2  Short offline       Completed without error       00%         0         -

However, after running
# smartctl -t long -d sat /dev/sdc
I have no indication that it has been passed:
# smartctl -t long -d sat /dev/sdc
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.6-gentoo] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Extended self-test routine immediately
in off-line mode".
Drive command "Execute SMART Extended self-test routine immediately in
off-line mode" successful.
Testing has begun.
Please wait 571 minutes for test to complete.
Test will complete after Fri Sep  2 04:02:18 2016

Use smartctl -X to abort test.

Fri Sep 2 6:10
# smartctl -l selftest -d sat /dev/sdc
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.6-gentoo] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

Read Device Identity failed: scsi error device will be ready soon

A mandatory SMART command failed: exiting. To continue, add one or
more '-T permissive' options.

# smartctl -a -d sat /dev/sdc
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.6-gentoo] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD50EZRZ-00GZ5B1
Serial Number:   <snipped>
LU WWN Device Id: <snipped>
Firmware Version: 80.00A80
User Capacity:    5,000,981,078,016 bytes [5.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5700 rpm
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Fri Sep  2 06:12:50 2016 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x80)    Offline data collection activity
                    was never started.
                    Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)    The previous self-test
routine completed
                    without error or no self-test has ever
                    been run.
Total time to complete Offline
data collection:         (57180) seconds.
Offline data collection
capabilities:              (0x7b) SMART execute Offline immediate.
                    Auto Offline data collection on/off support.
                    Suspend Offline collection upon new
                    command.
                    Offline surface scan supported.
                    Self-test supported.
                    Conveyance Self-test supported.
                    Selective Self-test supported.
SMART capabilities:            (0x0003)    Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01)    Error logging supported.
                    General Purpose Logging supported.
Short self-test routine
recommended polling time:      (   2) minutes.
Extended self-test routine
recommended polling time:      ( 571) minutes.
Conveyance self-test routine
recommended polling time:      (   5) minutes.
SCT capabilities:            (0x3035)    SCT Status supported.
                    SCT Feature Control supported.
                    SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE
UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   253   051    Pre-fail
Always       -       0
  3 Spin_Up_Time            0x0027   198   198   021    Pre-fail
Always       -       9083
  4 Start_Stop_Count        0x0032   100   100   000    Old_age
Always       -       7
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail
Always       -       0
  7 Seek_Error_Rate         0x002e   100   253   000    Old_age
Always       -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age
Always       -       1
 10 Spin_Retry_Count        0x0032   100   253   000    Old_age
Always       -       0
 11 Calibration_Retry_Count 0x0032   100   253   000    Old_age
Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age
Always       -       7
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age
Always       -       1
193 Load_Cycle_Count        0x0032   200   200   000    Old_age
Always       -       10
194 Temperature_Celsius     0x0022   124   105   000    Old_age
Always       -       28
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age
Always       -       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age
Always       -       0
198 Offline_Uncorrectable   0x0030   100   253   000    Old_age
Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age
Always       -       0
200 Multi_Zone_Error_Rate   0x0008   100   253   000    Old_age
Offline      -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining
LifeTime(hours)  LBA_of_first_error
# 1  Conveyance offline  Completed without error       00%         0         -
# 2  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

Reply via email to